This is to test the PTPHQA reporting capabilities of a Windows Precision Touchpad device.
Test name
- Test.PTPHQA
Core requirements tested
- Device.Input.PrecisionTouchpad.HIDCompliance.PTPHQA
Test purpose
Verifies that the device is able to report a PTPHQA certification blob.
Test only checks that the usage is available. For Windows 8.1 compatibility, the device is responsible for accurately reporting its PTPHQA blob.
Tools required
- PTLogo.exe
Validation steps
Launch Test.PTPHQA.json.
PTLogo will automatically pass, if the device correctly reports the PTPHQA usage. Conversely, the test will fail if the PTPHQA usage is incorrectly reported.
Here's a screenshot from the test, showing a passing result.
Note If this is a re-certification, this test will fail and should be manually verified by entering the following command: GetThqaBlob.exe –usage=TouchPad -verifyCertified
Common error messages
- None.
Passing criteria
- 1/1 (100%) iterations must pass in order to complete with passing status.