This is to test the maximum number of contacts supported by a Windows Precision Touchpad device.
Test name
- Test.MinMaxContacts.json
Core requirements tested
- Device.Digitizer.PrecisionTouchPad.Performance.MinMaxContacts
Test purpose
- Verifies that the device is able to support between 3 and 5 simultaneous contacts.
Tools required
- PTLogo.exe
Validation steps
Launch Test.MinMaxContacts.json.
PTLogo will automatically pass or fail depending on the maximum number of contacts the touchpad device supports.
Common error messages
"[23] device doesn’t support minimum number of contacts:#"
o The device supports less than three contact minimum.
o The displayed value (#) indicates the number of supported contacts.
"[24] device supports too many contacts:#"
o The device supports more than a maximum of five contacts.
o The displayed value (#) indicates the number of supported contacts.
Passing criteria