Edit

Share via


New-CsWatcherNodeConfiguration

Assigns a new collection of watcher node configuration settings to a pool. Watcher nodes are computers that periodically use Microsoft System Center Operations Manager and Skype for Business Server synthetic transactions to verify that Skype for Business Server components are working as expected. This cmdlet was introduced in Lync Server 2013.

Syntax

Identity

New-CsWatcherNodeConfiguration
    [-Identity] <XdsGlobalRelativeIdentity>
    -PortNumber <UInt16>
    [-Confirm]
    [-Enabled <Boolean>]
    [-ExtendedTests <PSListModifier>]
    [-Force]
    [-InMemory]
    [-Tests <PSListModifier>]
    [-TestUsers <PSListModifier>]
    [-UseInternalWebUrls <Boolean>]
    [-WhatIf]
    [-XmppTestReceiverMailAddress <String>]
    [-UseAutoDiscovery <Boolean>]
    [<CommonParameters>]

ParentAndRelativeKey

New-CsWatcherNodeConfiguration
    -PortNumber <UInt16>
    -TargetFqdn <String>
    [-Confirm]
    [-Enabled <Boolean>]
    [-ExtendedTests <PSListModifier>]
    [-Force]
    [-InMemory]
    [-Tests <PSListModifier>]
    [-TestUsers <PSListModifier>]
    [-UseInternalWebUrls <Boolean>]
    [-WhatIf]
    [-XmppTestReceiverMailAddress <String>]
    [-UseAutoDiscovery <Boolean>]
    [<CommonParameters>]

Description

If you are using Microsoft System Center Operations Manager to monitor Skype for Business Server then you have the option of setting up "watcher nodes": computers that periodically and automatically, run synthetic transactions in order to verify that Skype for Business Server is working as expected. Watcher nodes are assigned to pools, and are managed using the CsWatcherNodeConfiguration cmdlets. Note that you do not need to install watcher nodes if you are using System Center Operations Manager. You can still monitor your system without using watcher nodes; the only difference is that any synthetic transactions you want to run will need to be invoked manually rather than automatically invoked by Operations Manager.

Skype for Business Server Control Panel: The functions carried out by the New-CsWatcherNodeConfiguration cmdlet are not available in the Skype for Business Server Control Panel.

Examples

Example 1

Set-CsTestUserCredential -SipAddress "sip:kenmyer@litwareinc.com" -UserName "litwareinc\kenmyer" -Password "07Apples"

Set-CsTestUserCredential -SipAddress "sip:pilar@litwareinc.com" -UserName "litwareinc\pilar" -Password "07Apples"

$x = New-CsExtendedTest -TestUsers "sip:kenmyer@litwareinc.com", "sip:pilar@litwareinc.com" -Name "PSTN Test" -TestType "PSTN"

New-CsWatcherNodeConfiguration -TargetFqdn "atl-cs-001.litwareinc.com" -PortNumber 5061 -TestUsers "sip:kenmyer@litwareinc.com","sip:pilar@litwareinc.com"} -ExtendedTests @{Add=$x}

The commands shown in Example 1 create a new collection of watcher node configuration settings for the pool atl-cs-001.litwareinc.com. To do this, the first two commands in the example create a pair watcher node test users (sip:kenmyer@litwareinc.com and sip:pilar@litwareinc.com). After the test users have been created, the third command in the example creates a new extended PSTN test using the two newly-created users. This new test (which, at this point in time, exists only in memory) is stored in a variable named $x.

Finally, the fourth command in the example creates the watcher node configuration settings for atl-cs-001.litwareinc.com. These new settings use port 5061; the two new test users and the extended test stored in the variable $x.

Parameters

-Confirm

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Prompts you for confirmation before executing the command.

Parameter properties

Type:SwitchParameter
Default value:None
Supports wildcards:False
DontShow:False
Aliases:cf

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Enabled

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Enables or disables the watcher node. The default value is True ($True).

Parameter properties

Type:Boolean
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-ExtendedTests

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

PSTN or Audio Conferencing Provider tests that can be assigned to a watcher node configuration. These tests must be created using the New-CsExtendedTest cmdlet and stored in a variable (for example, $x). The test can then be assigned to a watcher node by using syntax similar to this:

-ExtendedTests @{Add=$x}

Parameter properties

Type:PSListModifier
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Force

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Suppresses the display of any non-fatal error message that might occur when running the command.

Parameter properties

Type:SwitchParameter
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Identity

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Fully qualified domain name of the pool being associated with the watcher node configuration settings. You can use either the Identity parameter or the TargetFqdn parameter to specify the pool; however, you cannot use both these parameters in the same command.

Parameter properties

Type:XdsGlobalRelativeIdentity
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

Identity
Position:2
Mandatory:True
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-InMemory

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Creates an object reference without actually committing the object as a permanent change. If you assign the output of this cmdlet called with this parameter to a variable, you can make changes to the properties of the object reference and then commit those changes by calling this cmdlet's matching Set- cmdlet.

Parameter properties

Type:SwitchParameter
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-PortNumber

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

SIP port used by the Registrar service.

Parameter properties

Type:UInt16
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:True
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-TargetFqdn

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Fully qualified domain name of the pool being associated with the watcher node configuration settings. You can use either the TargetFqdn parameter or the Identity parameter to specify the pool; however, you cannot use both these parameters in the same command.

Parameter properties

Type:String
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

ParentAndRelativeKey
Position:Named
Mandatory:True
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Tests

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Synthetic transactions to be run by the watcher node. Allowed values are:

Registration

IM

GroupIM

P2PAV

AvConference

Presence

ABS

ABWQ

MCXP2PIM

ExumConnectivity

JoinLauncher

PersistentChatMessage

DataConference

XmppIM

UnifiedContactStore

AVEdgeConnectivity

To configure tests at the time you create a new watcher node, use the following syntax, separating the individual tests by using commas:

-Tests "ABS","ABWQ","IM","GroupIM","XmppIM"

Parameter properties

Type:PSListModifier
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-TestUsers

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

SIP addresses of the test users to be assigned to the watcher node; these user accounts must have previously been configured by using the Set-CsTestUserCredential cmdlet. To add test users, use syntax similar to this, separating user addresses by using commas:

-TestUsers "sip:kenmyer@litwareinc.com","sip:pilar@litwareinc.com"

Parameter properties

Type:PSListModifier
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-UseAutoDiscovery

Applicable: Skype for Business Server 2015, Skype for Business Server 2019

When set to True ($True), Skype for Business Online watcher nodes will use the Autodiscover service to locate the target pool. When set to False (the default value) watcher nodes will use SRV records to locate the pool.

Parameter properties

Type:Boolean
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-UseInternalWebUrls

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

When set to True ($True), instructs the watcher node to use the internal Web URLs rather than the external Web URLs. This provides a way to way to verify URL validity for users located behind the organization's firewall.

Parameter properties

Type:Boolean
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-WhatIf

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

Describes what would happen if you executed the command without actually executing the command.

Parameter properties

Type:SwitchParameter
Default value:None
Supports wildcards:False
DontShow:False
Aliases:wi

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-XmppTestReceiverMailAddress

Applicable: Lync Server 2013, Skype for Business Server 2015, Skype for Business Server 2019

XMPP email address to be used when testing the XMPP gateway.

Parameter properties

Type:String
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable, -ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

Inputs

None

The New-CsWatcherNodeConfiguration cmdlet does not accept pipelined input.

Outputs

Microsoft.Rtc.Management.WritableConfig.Settings.WatcherNode.TargetPool

The New-CsWatcherNodeConfiguration cmdlet creates new instances of the Microsoft.Rtc.Management.WritableConfig.Settings.WatcherNode.TargetPool#Decorated object.