Edit

Share via


Get-MailTrafficSummaryReport

This cmdlet is available only in the cloud-based service.

Use the Get-MailTrafficSummaryReport cmdlet to view summary information about message traffic in your organization for the last 90 days.

For information about the parameter sets in the Syntax section below, see Exchange cmdlet syntax.

Syntax

Default (Default)

Get-MailTrafficSummaryReport
    [-Category <String>]
    [-DlpPolicy <MultiValuedProperty>]
    [-Domain <MultiValuedProperty>]
    [-EndDate <DateTime>]
    [-Page <Int32>]
    [-PageSize <Int32>]
    [-ProbeTag <String>]
    [-StartDate <DateTime>]
    [-TransportRule <MultiValuedProperty>]
    [<CommonParameters>]

Description

This cmdlet has C1, C2 and C3 as header names and the meaning of them depends on the category you choose. Next you can see an explanation about each category:

  • InboundTransportRuleHits and OutboundTransportRuleHits: C1 is the transport rule name, C2 the audit level and C3 the hits.
  • TopSpamRecipient, TopMailSender, TopMailRecipient and TopMalwareRecipient: C1 is the recipient or sender and C2 the quantity of email messages.
  • TopMalware: C1 is the malware name and C2 the quantity of appearances.

You need to be assigned permissions before you can run this cmdlet. Although this article lists all parameters for the cmdlet, you might not have access to some parameters if they aren't included in the permissions assigned to you. To find the permissions required to run any cmdlet or parameter in your organization, see Find the permissions required to run any Exchange cmdlet.

Examples

Example 1

Get-MailTrafficSummaryReport -Category TopSpamRecipient -StartDate 06/13/2015 -EndDate 06/15/2015

This example shows the top spam recipient statistics between June 13, 2015 and June 15, 2015.

Parameters

-Category

Applicable: Exchange Online, Exchange Online Protection

The Category parameter filters the report by category. Valid values are:

  • InboundDLPHits
  • OutboundDLPHits
  • InboundTransportRuleHits
  • OutboundTransportRuleHits
  • InboundDLPPolicyRuleHits
  • OutboundDLPPolicyRuleHits
  • TopSpamRecipient
  • TopMailSender
  • TopMailRecipient
  • TopMalwareRecipient
  • TopMalwareAtpRecipient
  • TopMalware
  • TopPhishRecipient
  • TopPhishAtpRecipient
  • TopIntraOrgRecipient
  • TopIntraOrgSender
  • TopIntraOrgSpamRecipient
  • TopIntraOrgMalwareRecipient
  • TopIntraOrgPhishRecipient
  • TopIntraOrgPhishAtpRecipient
  • TopIntraOrgMalwareAtpRecipient
  • TopComplianceTagActivityCount
  • TopComplianceTagActivityCountByDay

Parameter properties

Type:String
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-DlpPolicy

Applicable: Exchange Online, Exchange Online Protection

The DlpPolicy parameter filters the report by the name of the data loss prevention (DLP) policy. You can specify multiple values separated by commas. If the value contains spaces, enclose the value in quotation marks (").

Parameter properties

Type:MultiValuedProperty
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Domain

Applicable: Exchange Online, Exchange Online Protection

The Domain parameter filters the results by an accepted domain in the cloud-based organization. You can specify multiple domain values separated by commas, or the value All.

Parameter properties

Type:MultiValuedProperty
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:True
Value from pipeline by property name:True
Value from remaining arguments:False

-EndDate

Applicable: Exchange Online, Exchange Online Protection

The EndDate parameter specifies the end date of the date range.

Use the short date format that's defined in the Regional Options settings on the computer where you're running the command. For example, if the computer is configured to use the short date format MM/dd/yyyy, enter 09/01/2018 to specify September 1, 2018. You can enter the date only, or you can enter the date and time of day. If you enter the date and time of day, enclose the value in quotation marks ("), for example, "09/01/2018 5:00 PM".

Parameter properties

Type:DateTime
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Page

Applicable: Exchange Online, Exchange Online Protection

The Page parameter specifies the page number of the results you want to view. Valid input for this parameter is an integer between 1 and 1000. The default value is 1.

Parameter properties

Type:Int32
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-PageSize

Applicable: Exchange Online, Exchange Online Protection

The PageSize parameter specifies the maximum number of entries per page. Valid input for this parameter is an integer between 1 and 5000. The default value is 1000.

Parameter properties

Type:Int32
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-ProbeTag

Applicable: Exchange Online, Exchange Online Protection

This parameter is reserved for internal Microsoft use.

Parameter properties

Type:String
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-StartDate

Applicable: Exchange Online, Exchange Online Protection

The StartDate parameter specifies the start date of the date range.

Use the short date format that's defined in the Regional Options settings on the computer where you're running the command. For example, if the computer is configured to use the short date format MM/dd/yyyy, enter 09/01/2018 to specify September 1, 2018. You can enter the date only, or you can enter the date and time of day. If you enter the date and time of day, enclose the value in quotation marks ("), for example, "09/01/2018 5:00 PM".

Parameter properties

Type:DateTime
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-TransportRule

Applicable: Exchange Online, Exchange Online Protection

The TransportRule parameter filters the report by the name of the transport rule. You can specify multiple values separated by commas. If the value contains spaces, enclose the value in quotation marks (").

Parameter properties

Type:MultiValuedProperty
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable, -ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

Inputs

Input types

To see the input types that this cmdlet accepts, see Cmdlet Input and Output Types. If the Input Type field for a cmdlet is blank, the cmdlet doesn't accept input data.

Outputs

Output types

To see the return types, which are also known as output types, that this cmdlet accepts, see Cmdlet Input and Output Types. If the Output Type field is blank, the cmdlet doesn't return data.