Get-NetQosFlowControl
Gets the priority-based flow control settings.
Syntax
ByIfAlias (Default)
Get-NetQosFlowControl
[[-Priority] <Byte[]>]
[[-InterfaceAlias] <String>]
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[<CommonParameters>]
ByIfIndex
Get-NetQosFlowControl
[[-Priority] <Byte[]>]
[[-InterfaceIndex] <UInt32>]
[-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>]
[-AsJob]
[<CommonParameters>]
Description
The Get-NetQosFlowControl cmdlet gets the priority-based flow control (PFC) settings programmed in Windows Server® 2012 and later.
For more information about PFC, see the Enable-NetQosFlowControl cmdlet.
PFC is part of the IEEE data center bridging (DCB) standard.
Examples
Example 1: Display flow control settings
PS C:\> Get-NetQosFlowControl
Priority Enabled
-------- -------
0 False
1 False
2 False
3 True
4 False
5 False
6 False
7 False
This command displays flow control settings.
Parameters
-AsJob
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
The cmdlet immediately returns an object that represents the job and then displays the command prompt.
You can continue to work in the session while the job completes.
To manage the job, use the *-Job
cmdlets.
To get the job results, use the Receive-Job cmdlet.
For more information about Windows PowerShell background jobs, see about_Jobs.
Parameter properties
Type: | SwitchParameter |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-CimSession
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.
Parameter properties
Type: | CimSession[] |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Aliases: | Session |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-InterfaceAlias
The Get-NetQosFlowControl cmdlet gets the priority-based flow control (PFC) settings programmed in Windows Server® 2012 and later.
For more information about PFC, see the Enable-NetQosFlowControl cmdlet.
PFC is part of the IEEE data center bridging (DCB) standard.
Parameter properties
Type: | String |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Aliases: | IfAlias |
Parameter sets
ByIfAlias
Position: | 1 |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | True |
Value from remaining arguments: | False |
-InterfaceIndex
The Get-NetQosFlowControl cmdlet gets the priority-based flow control (PFC) settings programmed in Windows Server® 2012 and later.
For more information about PFC, see the Enable-NetQosFlowControl cmdlet.
PFC is part of the IEEE data center bridging (DCB) standard.
Parameter properties
Type: | UInt32 |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Aliases: | IfIndex |
Parameter sets
ByIfIndex
Position: | 1 |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | True |
Value from remaining arguments: | False |
-Priority
The Get-NetQosFlowControl cmdlet gets the priority-based flow control (PFC) settings programmed in Windows Server® 2012 and later.
For more information about PFC, see the Enable-NetQosFlowControl cmdlet.
PFC is part of the IEEE data center bridging (DCB) standard.
Parameter properties
Type: | Byte[] |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
(All)
Position: | 0 |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
-ThrottleLimit
The Get-NetQosFlowControl cmdlet gets the priority-based flow control (PFC) settings programmed in Windows Server® 2012 and later.
For more information about PFC, see the Enable-NetQosFlowControl cmdlet.
PFC is part of the IEEE data center bridging (DCB) standard.
Parameter properties
Type: | Int32 |
Default value: | None |
Supports wildcards: | False |
DontShow: | False |
Parameter sets
(All)
Position: | Named |
Mandatory: | False |
Value from pipeline: | False |
Value from pipeline by property name: | False |
Value from remaining arguments: | False |
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable, -ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Inputs
String
UInt32
Outputs
CimInstance
CimInstance
The Microsoft.Management.Infrastructure.CimInstance
object is a wrapper class that displays Windows Management Instrumentation (WMI) objects.
The path after the pound sign (#
) provides the namespace and class name for the underlying WMI object.
This cmdlet returns a MSFT_NetQosFlowControlSettingData object that contains the flow control settings per priority.